Preparation work before powder feeding of pulse bag filter

May 20, 2024

Preparation work before powder feeding of pulse bag filter

Before starting to feed powder into the pulse bag filter, determine the air volume of the induced draft fan. Above 70, the required bypass valve is closed and the lift valve is online. The fan runs under load until the pre coating is completed. After a few minutes, I thought they were evenly and smoothly distributed in each ash hopper. When pre coating, the rising pressure difference in each room is reflected. For example, if the pressure difference is initially 100Pa, it should be reduced to 350-400Pa after pre coating, which is an increase of 250-300Pa. If not, it indicates that pre coating has failed and needs to be redone.

Normally, the dust concentration at the inlet and outlet of a pulse bag filter is allowed. Below 30g/Nm3, if there are requirements, the design can be based on the user's needs. Pulse dust collectors are divided into three different series, single row and double row, based on the different diameters of the filter bags, the different layouts of the filter bags in each room, and the different filtration areas. The pulse blowing pressure can be low pressure. (0.2-0.3Mpa), It can also be used for high pressure (0.4-0.5Mpa), which can be selected by the user; Double row arrangement, pulse blowing pressure is generally designed as low pressure (0.2-0.3Mpa); Double row arrangement, pulse blowing pressure is high pressure (0.4-0.5Mpa). If the user has a request, it can also be based on the user's opinion. Independently designed.

After the pre coating work of the pulse dust collector is completed, stop the fan and arrange personnel to enter the clean air chamber of the dust collector for inspection. If dust leakage is found at the flower plate hole or box welding point, the sealing performance between the pulse dust collector filter bag head and the flower plate should be checked for tightness. If it is not tight, it needs to be adjusted. After pre coating the filter bag of the pulse dust collector with dust, if there are no problems, the system will run to normal design parameters, and then the dust removal system of the dust collector will be turned on, and the dust collector will enter normal operation.

The pre coating of the pulse bag filter bag should be cut off and the dust removal system should be stopped before the combustion or production process begins. The inlet valve of the pulse dust collector (including the inlet and outlet valves of each filter bag chamber) should be opened. Start the fan and gradually increase the airflow of the dust collector until it reaches the designed air volume. Around 70, record the internal and external resistance of the dust collector filter bag in each room. Place the dry and oil-free pre coated powder into the opening of the dust collector's main inlet duct (usually the flue gas testing port). The mesh size of grey powder should be less than 200 mesh and the moisture content should be less than 1. Put the ash powder in according to each filtering area of 350-450g.

Preparation work before powder feeding of pulse bag filter

Information
Contact Us
  • Tel: 15533772966
  • E-mail: 2788466241@qq.com
  • Add: 河北省沧州市泊头市经济开发区2号路
Follow Us